0

Shop

Home   /   Shop

ACRX Series

Description

BASIS EP offers a range of high voltage capacitor charging power supplies with output voltage from 10 kV to 50 kV and output power from 6 kJ/s to 12kJ/s.
The power supplies use the “H bridge” topology. The commutation loses are very low, so the efficiency is greater than 85%.
Due to conception, power supplies are protected from over currents, over voltages and no load fault conditions. The fan failure is associated with a temperature fault. All power supplies are equipped with an interlock, located on the rear panel.

Characteristics

Technical specifications 

Characterisitics Values
Input voltage 400 VAC / 3 phases with no neutral
Output power 6, 8, 10, or 12 kJ/s
Output voltage 10 kV, 15 kV, 20 kV, 25 kV, 40 kV or 50 kV
Polarity Positive / Negative / Floating  (up to 10 kV)
Inrush current < 3 x In (during 100 ms maxi)
Efficiency > 85%
Telemetries accuracies +/- 0,5% of the full scale
Output voltage programming 10 to 100% of the full scale
Storage temperature 0°C to 85°C (30°F to 185 °F)
Operating temperature + 10°C to 35°C (30°F to 95 °F)
Humidity 40% to 90% no-condensing
EN standards Safety requirements: EN 61010-1 : 2001
EMC Emission : EN 61000-6-4 : 2001
EMC Immunity : EN 61000-6-2 : 2001

Human-Machine Interface

The power supplies can be operated in remote mode (0-10V program and monitor). The analog programming, analog monitoring, faults and controls are available on the 25 pins Sub-D connector. On the front panel, lights are available to indicate the power supplies status.

Instrumented

In the instrumented version, output voltage can be adjusted on the front panel. The screen displays voltage/current programming and monitoring. If a fault occurs, it will be displayed on the screen.

RS232 / Ethernet

Ethernet/RS232 communications are available as an option. A 9 pins Sub-D connector and a RJ45 connector are located on the rear panel. It is easy to connect the computer with a standard software and to drive the power supply.

Optical Fibers

Optical fibers are useful to drive the power supply ensuring data transmission in a perturbed environment. Moreover, electrical insulation is warranted between the power supplies and the control station.

Mechanical

The power supplies are integrated inside a standard 19 inches rack, 5U height (222mm/ 8.74 in). The depth is between 510 mm and 600 mm, depending on input voltage and power output.

All power supplies are delivered with a HV plug and a 3 meters length high voltage cable (9.8ft).