Description
BASIS EP offers a range of high voltage capacitor charging power supplies with output voltage from 10 kV to 50 kV and output power from 6 kJ/s to 12kJ/s.
The power supplies use the “H bridge” topology. The commutation loses are very low, so the efficiency is greater than 85%.
Due to conception, power supplies are protected from over currents, over voltages and no load fault conditions. The fan failure is associated with a temperature fault. All power supplies are equipped with an interlock, located on the rear panel.
Characteristics
Technical specifications
Characterisitics | Values |
Input voltage | 400 VAC / 3 phases with no neutral |
Output power | 6, 8, 10, or 12 kJ/s |
Output voltage | 10 kV, 15 kV, 20 kV, 25 kV, 40 kV or 50 kV |
Polarity | Positive / Negative / Floating (up to 10 kV) |
Inrush current | < 3 x In (during 100 ms maxi) |
Efficiency | > 85% |
Telemetries accuracies | +/- 0,5% of the full scale |
Output voltage programming | 10 to 100% of the full scale |
Storage temperature | 0°C to 85°C (30°F to 185 °F) |
Operating temperature | + 10°C to 35°C (30°F to 95 °F) |
Humidity | 40% to 90% no-condensing |
EN standards | Safety requirements: EN 61010-1 : 2001 EMC Emission : EN 61000-6-4 : 2001 EMC Immunity : EN 61000-6-2 : 2001 |
Human-Machine Interface
The power supplies can be operated in remote mode (0-10V program and monitor). The analog programming, analog monitoring, faults and controls are available on the 25 pins Sub-D connector. On the front panel, lights are available to indicate the power supplies status.
Instrumented
In the instrumented version, output voltage can be adjusted on the front panel. The screen displays voltage/current programming and monitoring. If a fault occurs, it will be displayed on the screen.
RS232 / Ethernet
Ethernet/RS232 communications are available as an option. A 9 pins Sub-D connector and a RJ45 connector are located on the rear panel. It is easy to connect the computer with a standard software and to drive the power supply.
Optical Fibers
Optical fibers are useful to drive the power supply ensuring data transmission in a perturbed environment. Moreover, electrical insulation is warranted between the power supplies and the control station.
Mechanical
The power supplies are integrated inside a standard 19 inches rack, 5U height (222mm/ 8.74 in). The depth is between 510 mm and 600 mm, depending on input voltage and power output.
All power supplies are delivered with a HV plug and a 3 meters length high voltage cable (9.8ft).